Biomarker Data

Structured reference data for the veterinary biomarkers measured on the Migibio FICT platform. Each biomarker has a dedicated data card with reference ranges, clinical cutoffs, and assay-specific analytical performance.

Data Card Index

Biomarker Organ / System Species Data Card
SDMA Kidney (renal function) Canine, Feline Open →
NT-proBNP Heart (cardiac) Canine, Feline Open →
CRP Acute-phase (inflammation) Canine Open →
SAA Acute-phase (inflammation) Feline Open →
Cystatin C Kidney (renal function) Canine, Feline (see Reference Ranges)

Quick Reference — Key Cutoffs

Biomarker Species Reference Range Key Cutoff
SDMA Canine / Feline 0–14 µg/dL > 14 µg/dL → evaluate; ≥ 18 → IRIS staging
NT-proBNP Canine < 900 pmol/L > 900 pmol/L → cardiac concern
CRP Canine < 10 mg/L > 10 mg/L → inflammation
SAA Feline < 5 mg/L > 5 mg/L → inflammation

These are summary cutoffs. Full interpretation tables are on each data card, and the authoritative document is the product IFU.

How to Use This Data

  1. Find the biomarker in the index above.
  2. Open its data card for reference ranges, interpretation tables, and analytical performance.
  3. Cross-reference with the Reference Ranges section for species-specific intervals and the Assay Performance section for LOD/CV%.

Data Provenance

Each numeric value traces to a Migibio validation report or a recognized veterinary reference. Migibio-specific figures are labeled as such. See About the Data Hub for the full provenance policy.

FAQ

Are these reference ranges universal? Reference ranges are species- and often breed/age-dependent. The values here are general adult reference ranges; individual patients may vary. Confirm against your local reference population.

Where is the authoritative cutoff? The product IFU is the legally controlling document. This data hub is a technical reference, not a substitute for the IFU.

Why does SDMA use the same range for dogs and cats? The 0–14 µg/dL reference range is common to both species in current veterinary guidelines (IRIS), though staging thresholds may differ slightly. See the SDMA data card for details.

Authored by: Migibio Clinical & Scientific Affairs, Guangzhou Magic Biotech Co., Ltd.

Reviewed by: Migibio R&D Quality Committee

Last updated: 2026-08-13

Disclosure: Migibio (Guangzhou Magic Biotech Co., Ltd.) is the manufacturer of the FIA680/FIA880 analyzers and FICT reagents referenced in this content. See our Editorial & Review Policy.

Contact: Martin.Wong  ·  Phone (WhatsApp): +86 13323237275  ·  Email: martinwang2024@gmail.com
Back to top